Draft version of RIR
This draft RIR is merely for information purposes and is not legally binding at the time of this publication and their contents can still undergo important modifications until officially released.
Nr | Parameter2) | Description | Comments |
1 | Radiocommunication service | - | - |
2 | Application | LP FM Transmitter | - |
3 | Frequency band | 87.500 - 108.000 MHz | Band II LPD shall operate on user selectable frequencies within the 87.6 to 107.9 MHz frequency range. |
4 | Channelling | - | Selectable frequency steps of 50 kHz, 100 kHz or 200 kHz. |
5 | Modulation / Occupied bandwidth | FM / max. 200 kHz | - |
6 | Direction / Separation | - | - |
7 | Transmit power / Power density | Max. 50 nW e.r.p. | Integral antenna |
8 | Channel access and occupation rules | According to harmonised standard: Band II LPD shall cease to transmit within 1 minute of removal of the audio input signal. | Pilot tones to ensure continuity of transmission are not permitted. |
9 | Authorisation regime | Switzerland: License exempt. Liechtenstein: General authorisation. | Operation on NIB / NPB. (Non interference basis / non protection basis). |
10 | Additional essential requirements | - | - |
11 | Frequency planning assumptions | EN 301 357 | Clause 8.2 and 8.3 |
12 | Planned changes | - | - |
13 | Reference | EN 301 357 /-/ ERC/REC 70-03, Annex 10. | Effective use of spectrum / ECC Decisions / ECC Recommendations. |
14 | Notification number | tbd. | - |
15 | Remarks | EN 301 489-9 | - |
Normative part: 1 to 11
Informative part: Nr 12 to 15
1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/en/technical-interface-regulations
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000
© OFCOM (Swiss Federal Office of Communications)